Orbscan interpretation download youtube

Zywave ii slc 01027 orbscan hz zyoptics ii diagnostic workstation topographer for sale auction. In addition it helps the attendees understand and interpret topography maps from different commercially available topography units, and discusses the strengths and limitations of different topographers in clinical practice. The pentacam oculus is one of a number of rotating scheimpflug imaging systems produced in germany. Pdf comparison of the orbscan ii topographer and the. Instead of a dome like figure, it becomes like a cone distorts and reduces vision usually bilaterally but asymmetrical usually myopic with large amounts of irregular astigmatism no corneal refractive surgeries can be done as the cornea steepens. Julie rodman presents optical coherence tomography oct 101. As you probably know, the weakest point of the orbscan is the computer. Unlike current topography systems which scan the surface of the eye at standard points, the orbscan ii acquires. None of the equipment posted for sale on is owned by medwow, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page. Data regarding the corneal pachymetry and anterior chamber depth. The new platform, which features multiple enhancements driven by more than 20 years of field use and research, is designed to serve as an indispensable screening tool to the increasing number of ophthalmic.

The most popular topographer out there and has been the gold standard for quite some time. If you like this video, please do not forget to visit and subscribe my website for more resources and information which i am building. The researchers admit the orbscan s limitations and possible sources of error, as well as the relatively small sample size, limit their findings. So the orbscan uses the slit, but it also has the reflective technology to analyze the surface.

Measurement of angle kappa with orbscan ii and galilei g4. To measure angle kappa distance with orbscan ii and galilei g4, and to evaluate possible variations in this value for different accommodation degrees. If you like this video, please do not forget to visit and subscribe my website s. The orbscan uses an algorithm to calculate the corneal irregularity indices in the 3. This study tests the hypothesis that the keratometric value derived from orbscan ii mean power maps, when used in an intraocular lens iol calculation formula, at a specific measurement zone, will accurately determine the power of an iol for planned cataract surgery in patients who have undergone prior myopic laserassisted in situ keratomileusis lasik. So when we have angular reflected light, the angle. Is the orbscan or pentacam more accurate for determining if im a good candidate for lasik.

This is a complete system and includes a 6 month parts and labor warranty. Zywave ii slc 01027 orbscan hz zyoptics ii diagnostic. Unlike current topography systems which scan the surface of. Comparison of the orbscan ii topographer and the itrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients. Keratoconus abnormal cornea condition where the cornea protrudes out more. Is the orbscan or pentacam more accurate for determining. The standard deviation of measurements was higher with orbscan ii as compared to ultrasonic pachymetry, but the difference was not statistically significant fig. Bausch and lomb orbscan iiz corneal analysis system. The orbscan technology takes pachymetry measurements optically without touching the cornea. In general, the orbscan iiz device measured lower values than either the tms4 topographer or the pentacam hr.

Conference donnee au centre victor hugo le 11 mars 2014. Why the video is playing instead of downloading on savefrom. Lecture on how to read orbscan iiz authorstream presentation. The second generation orbscan ii is a hybrid system that uses both projective slit scanning and reflective placido methods. Measurement of angle kappa with synoptophore and orbscan ii in a normal population. Reading corneal topography in a very simple and stepbystep way. Bausch and lomb topographer orbscan 2 model information. Additionally, the bad performs regression analysis on changes in anterior and posterior elevation, corneal. Once your video finishes downloading, rightclick it and then click show in folder in the resulting dropdown menu. Topografia, pentacam e orbscan by thiago correia on prezi. The following is a selection of chapters which we believe will be particularly useful and interesting to you. Orbscan topography is a newer technology that not only allows your surgeon to detect these irregularities on the front surface of the cornea, but also allows mapping of the posterior corneal surface. The j0 measurements were higher using the tms4 topographer compared with the orbscan iiz p 0.

The center box on the orbscan quadmap displays the corneal irregularity index figures figures1, 1,3, 3,6 6 and and7. This means that the standard scale intervals adopted in orbscan ii corneal topography are more than sufficient to match the users expectations with regard to the interpretation and the display of varying corneal patterns. Angle kappa was measured using the orbscan ii and the galilei g4 in the right eye of 80 patients aged from 20 to 40 years. Search and browse hundreds of medical equipment auctions on. Figure 10 a second device, the orbscan, manufactured by orbtek, acquires data from the diffuse reflection of a slit beam of light scanned across the cornea. This lecture discusses the evolution and principles of corneal topography in this lecture. Looking for more insight on how to pick the right oct system for your practice. This may lead to an emphasis on irrelevant details on the contour maps. Evaluation of orbscan ii corneal topography in individuals. This will cause a file explorer windows or finder mac window with your downloaded video to open, at which point you can doubleclick the video to play it in your computers default video player. Displays multiple and complete mathematical surfaces.

The images used to construct the anterior corneal surface,posterior corneal surface,anterior iris and anterior lens surfaces. The wide variety of maps can make orbscan bewildering. The solution to this issue, instead of left clicking the download video link, right click save as. This optical mapping or corneal topography system mapping system is a diagnostic tool that shows the overall architecture of the cornea including surface power, thickness, front and back shape. These items may be missing parts and the operating conditions are unknown. Conventional topography machines can only give information about the front surface. Compared with pentacam values, the postop changes with the orbscan were significantly greater for all posterior corneal parameters except pax5 p0. The mean, steep, and flat keratometry data were in better agreement using the tms4 topographer and the pentacam hr. Unlike current topography systems which scan the surface of the eye at standard points, the orbscan ii acquires over 9000 data points in 1. This device reflects a three dimensional grid of intersecting lines from the cornea. The orbscan ii also provides anterior segment data in the form of. Orbscan corneal topographer technology lasik flaum.

Central corneal thickness measurement by ultrasound versus. This property was used and turned in by the medical university of south carolina and is located in west columbia, south carolina. Feel free to comment down below to add to the theory about this big building. One such device is the cts or corneal topography system manufactured by par technologies. Measurement of angle kappa with synoptophore and orbscan. This value was measured three times per eye and per device, and the average was retained. A presentation based on assessment of corneal topography useful mainly for optometry students. This allows a measurement reading for the entire cornea. Licensed to youtube by sme on behalf of sony music entertainment. Utilizing a scanning slit measurement system, the orbscan ii provides the clinician with important diagnostic information about the cornea, iris, and lens. Bausch and lomb orbscan 2 topographer model information. With us, you can take advantage of some of the best pricing available along with the best. Aravind roy transcript to translate please select your language to.